Yokogawa IS8000 Integrated Software

POAExcluding Tax

Request a Quote

Description

Description

The Yokogawa IS8000 Integrated Software Platform streamlines the process of integrating, synchronizing, and measuring data. Add-on software packages give this test and measurement software evolving capabilities.

Serial Bus Analysis(SB1)

This is an analysis function for CAN bus communication widely used in in-vehicle networks and other applications. It enables decoding of communication contents, frame display, and search for specific information in CAN bus communication signal. This new serial bus analysis option can also be used to analyze signal waveforms acquired not only by Yokogawa’s oscilloscopes but also by the ScopeCorder series and IS8000. It is effective for reanalysis of communication signal waveforms previously measured, and for comparison and analysis with other physical quantity measurements.

Modbus/TCP Communication(MB1)

Modbus/TCP communication. A communication configuration file for connection to the YOKOGAWA GM10 and VZ20X recorders is included with the software. Other Modbus/TCP communication devices can also be connected to the IS8000 by creating a communication configuration file using the included tool. Integration of these devices with a Yokogawa Test & Measurement’s power analyzer and waveform measuring instrument by the IS8000 will provide a measurement system that supports more input channels, longer recording times and a wider variety of temperature sensors.

The Power of One

The IS8000 software platform is an integrated solution that accelerates engineering workflow. It is a revolutionary software solution that tightly integrates the timing, control, and data collection from multiple instruments, creating a comprehensive measurement suite that delivers high confidence, efficiency, and unity.

 

Specification

Supported devices

Functions Supported devices
Online data acquisition DL950, WT5000
Remote control and setting, acquisition data download DL350, DL850 series, DL950, DLM3000 series, DLM5000 series, DLM5000HD series, WT5000 (Remote control and setting only)
Data File Import DL350, DL850 series, DL950, DL750 (Only WVF file), SL1400 (Only WVF file) , SL1000, WT1800 series, WT3000 series, WT5000, DLM2000 series, DLM3000 series, DLM4000 series, DLM5000 series, DLM5000HD series
High-speed camera Sync.
(FS1 option)
Supported cameras for online sync.: Photron’s FASTCAM SA-Z, MIni UX*/AX/WX series, NOVA S series, NOVA R2
Supported devices for online sync.: DL950
Modbus/TCP Communication
(MB1 option)
Devices supported Modbus/TCP protocol.
ECU Monitor sync.
(EM1 option)
DTS INSIGHT’s RAMScope GT170(only for the variable data acquisition and calibration module), GT122

* Pre-trigger recording and multi-trigger recording using the Mini UX series in combination with the FS1 option are not supported.

Main specifications

The writings in red are changes from the previous version.

Ver. 24.1.2.0
Connecting support firmware DL950 Ver.1.50 or later
WT5000 Ver. 3.61 (upcoming) or later
Languages English / Chinese / Japanese
PC requirements For data acquisition with 10 Gb Ethernet connection;
CPU: Desktop PC required
Intel Core i7-1165G7 or later Intel CPU
4 cores(8 threads) or more 4.7 GHz or faster
Amount of memory: 16 GB or more
Amount of SSD: 512 GB or more
(M.2 slot is recommended, Sequential read/write 3 GB/s or faster)For data acquisition with 1 Gb Ethernet
/USB connection and offline analysis;
CPU: Intel Core i5-10210U or later Intel CPU
4 cores(8 threads) or more 4.2 GHz or faster
Amount of memory: 8 GB or more
Amount of SSD: 256 GB or more
(Sequential read/write 400 MB/s or faster)
OS Windows 11 Pro or Enterprise edition (except EM1 option)
Windows 10 64bit Pro or Enterprise edition
Communication interface USB (USBTMC / VISA), Ethernet (VXI-11, HiSLIP, Modbus/TCP *8)
Display resolution 1366×768 dots or higher, 100 % zoom
Number of connectable units (SY1 option) Up to 5 units
(Only one unit without SY1 option)
(SY1 option is required even if the time synchronisation is not used)
Supported file format WDF DL350, DL850 series, DL950, SL1000, DLM2000 series, DLM3000 series, DLM4000 series, DLM5000 series,DLM5000HD series
CSV (Waveform data) DL950, DL850 series, DL350, DLM5000HD/5000/4000/3000/2000 series, Xviewer Application Software and IS8000 *6
CSZ IS8000 CSV data compressed in ZIP format
CSV (Power measurement data)*2 WT5000
(without multi-unit sync. based on IEEE1588 PTP)
WT5000
(with multi-unit sync. based on IEEE1588 PTP.)
WT3000 series*1
WT1800 series
WVF DL750, SL1400
MD4 IS8000 data files
ASAM MDF 4.1 files
mepjt, anpjt IS8000 Project files
Export file formats ASAM MDF 4.1 files (mf4), ASCII files (csv), CSV files compressed in ZIP format (csz)
Online data acquisition
(DL950)*7
Motion mode Scope mode (Trigger/ Free-run)*4
The trigger mode cannot be used with multi-unit synchronized DL950s.
Maximum transfer rate 10G Ethernet connection: 320MB/s (20MS/s x 8ch, 10MS/s x 16ch)
1G Ethernet / USB connection: 6.4MB/s (200kS/s x 16ch)
Online data acquisition
(WT5000)*7
Monitoring/DAQ items Power trend graph and numeric
Harmonic bar graph *9
Data-streaming waveform *3
Vector diagram
Online data acquisition
(common)*7
Maximum continuous recording time/size The recording will be kept until free storage space falls below 10%.
Maximum recording channels 128 channel
Waveform overlays Aligned by time, absolute time ,head of data, end of data or arbitrary position
Automated waveform parameter measurements Up to 28 parameters (including P-P, Amp, RMS and Freq).
Display format Common TY-Overview (up to 32 ch for each group, up to 4 group), XY (up to 2 windows for each group), TY-View (up to 4 areas for each group), Numeric Monitor(Up to 128 channels)
For WT5000 Power trend graph and numeric display
Peak-to-peak compressed waveform (Data update interval: 1s or slower)
Bar graph of the amplitude and phase of each harmonic *9
Data streaming waveform display *3
Harmonic list display
Matrix display
Vector diagram
Automated waveform parameter measurements Automated measurement of history statistics Waveform parameters for each waveform in the historical memory and their statistics can be calculated automatically.
Automated measurement of cycle statistics Waveform parameters of each period of a cyclic waveform and their statistics can be calculated automatically.
Cursor Vertical, Horizontal, X-Y
Annotation function Comments, acquired data and calculated values can be added on the overview/view, waveform window and X-Y window.
Supported devices Data acquisition DL950
WT5000(760903 Current Sensor Element supported.10ms update rate supported.)
Flash ACQ data saving DL950
Data file import DL350, DL850 series, DL950, SL1000, WT1800 series, WT3000 series, WT5000, DLM2000 series, DLM3000 series, DLM4000 series, DLM5000 series,DLM5000HD series, DL750 (Only WVF files), SL1400 (Only WVF files)
Remote control and setting, acq. data download DL350, DL850 series, DL950, DLM3000 series, DLM5000 series,DLM5000HD series, WT5000(Remote control and setting only)
Screen Capture Save Clipboard, ping, jpg, gif
CSV batch converter Load MF4 (MDF4.1), WDF, WVF
Save CSV
Mathematical data analysis(/MH1) Number of Math channels Up to 16 channels
Operators +, -, x, /, Phase shift, ABS, SQRT, LOG, EXP, NEG, SIN, COS, TAN, ATAN, PH, DIF, DDF, INTEG, BIN, P2, P3, F1, F2, FV, PWHH, PWHL, PWLH, PWLL, PWXX, DUTYH, DUTYL, FLT1, FLT2, HLBT, MEAN
Number of computed points Up to 12.5 M points
or up to100 M points can be supported by installing MATLAB Runtime
Digital filters Gauss, Sharp, IIR(Butterworth)
FFT analysis (/MH1) Operator Type: LS, RS, PS, PSD, CS, TF, CH
Sub-type: REAL, IMAG, MAG, LOGMAG, PHASE
Window function Rect, Hanning, Flat top, Hamming
Number of FFT channels Up to 16 channels independently
Number of computed points Up to 2 M points
or up to100 M points can be supported by installing MATLAB Runtime
Serial bus analysis(/SB1) supported protocol CAN (CAN FD is not supported at present.)
Search target SOF, ID/Data, Error
Number of search points Up to 100,000 frames
Bit rate Select the value from 33.3kbps, 83.3kbps, 125kbps, 250kbps, 500kbps,1Mbps, or enter it within the range of 10kbps to 1Mbps in 0.1kbps steps.
High-speed camera Sync. (/FS1) Supported cameras for online sync Photron’s FASTCAM SA-Z, MIni UX*5/AX/WX series, NOVA S series, NOVA R2
Supported video format for online sync high-speed camera video files(avi)
Supported devices for online sync DL950
Supported video file formats for offline sync AVI(*.avi), MP4(*.mp4), WMV(*.wmv), AVCHD(*.mts), MOV(*.mov), MPEG2-PS(*.mpg, *.mpeg)
ECU Monitor sync.(EM1 option) Supported monitoring tools DTS INSIGHT’s RAMScope GT170(only for the variable data acquisition and calibration module), GT122
Supported data file RAMScopeVP output files(a2l)
Supported devices for online sync DL950

*1 Harmonic measurement data excluded.
*2 The measurement data of first 128 channels can be imported.
*3 /DS option is required for the WT5000 to be connected.
*4 Trigger DAQ with DL950 external clock input is not supported.
Freerun DAQ with DL950 external clock input, including 16-channel input module or CAN/CANFD/LIN/SENT module, is not supported.
*5 Pre-trigger recording and multi-trigger recording using the Mini UX series in combination with the FS1 option are not supported.
*6 Only CSV files saved with Ver. 22.6.1.0 or later IS8000 can be imported.
*7 Connecting instruments and collecting data with multiple launches of the IS8000 software on the same PC is not covered by the specification.
*8 MB1 option is required.
*9 G7 option on the connecting WT5000 is required to display measurement data complying with IEC 61000-4-7 Annex B (2k-9kHz).

Models and features

IS8000 Edition, License and Features

Models and features

No Reviews Yet

Write a Review

Share your thoughts. Be the first to leave a review.

Be the first to review “Yokogawa IS8000 Integrated Software”

Your email address will not be published. Required fields are marked *