Magna-Power MT Series

Categories: , Tag:

POAExcluding Tax

Request a Quote

Description

Description

Programmable DC Power Supply

Magna-Power Electronics MT Series uses the same reliable current-fed power processing technology and controls as the rest of the MagnaDC programmable power supply product line, but with larger high-power modules: individual 150 kW and 250 kW power supplies. The high-frequency IGBT-based MT Series units are among the largest standard switched-mode power supplies on the market, minimizing the number of switching components when comparing to smaller module sizes. Scaling in the multi-megawatts is accomplished using the UID47 device, which provides master-slave control: one power supply takes command over the remaining units, for true system operation. As an added safety measure, all MT Series units include an input AC breaker rated for full power.

250 kW modules come standard with an embedded 12-pulse harmonic neutralizer, ensuring low total harmonic distortion (THD). Even higher quality AC waveforms are available with an external additional 500 kW 24-pulse or 1000 kW 48-pulse harmonic neutralizers, designed and manufactured exclusively by Magna-Power for its MT Series products.


Key Features

  • 49 models
  • Heavy-duty floor-standing enclosure
  • Expandable into the multi-megawatts
  • 150 kW to 2,000 kW+ output power
  • 32 Vdc to 6000 Vdc output voltage
  • 25 Adc to 6000 Adc single unit output current
  • High-power harmonic neutralizers
  • SCPI Remote Programming API
  • High Accuracy Measurements
  • Programmable Protection Limits
  • NI LabVIEW™ and IVI Driver

Specification

The following specifications are subject to change without notice. Unless otherwise noted, all specifications measured at the product’s maximum ratings.

AC Input Specifications
Specification Value
3Φ AC Input Voltage

Available on all models

380/400 Vac (operating range 342 to 440 Vac)
415 Vac (operating range 373 to 456 Vac)
440 Vac (operating range 396 to 484 Vac)
480 Vac (operating range 432 to 528 Vac)
Input Frequency
50 Hz to 60 Hz
Power Factor
> 0.92 at maximum power, 100 kW and 150 kW models
> 0.96 at maximum power, 250 kW models
AC Input Isolation
±2500 Vdc, maximum input voltage to ground
DC Output Specifications
Specification Value
Voltage Ripple
Model specific. Refer to chart of available models.
Line Regulation
Voltage mode: ± 0.004% of full scale
Current mode: ± 0.02% of full scale
Load Regulation
Voltage mode: ± 0.01% of full scale
Current mode: ± 0.04% of full scale
Stability
± 0.10% for 8 hrs. after 30 min. warm-up
Efficiency
90% to 92%
Model specific. Refer to chart of available models.
Maximum Slew Rate

Standard Models

< 170 ms for a programmed output voltage change from 0 to 63%
< 200 ms for a programmed output current change from 0 to 63%
Maximum Slew Rate

Models with High Slew Rate Output (+HS) Option

< 5 ms for a programmed output voltage change from 0 to 63%
< 10 ms for a programmed output current change from 0 to 63%
Bandwidth

Standard Models

3 Hz with remote analog voltage programming
2 Hz with remote analog current programming
Bandwidth

Models with High Slew Rate Output (+HS) Option

60 Hz with remote analog voltage programming
45 Hz with remote analog current programming
DC Output Isolation

Models Rated ≤1000 Vdc

±1000 Vdc, maximum output voltage to ground
DC Output Isolation

Models Rated >1000 Vdc or Models with +ISO Option

±6000 Vdc, maximum output voltage to ground
Programming Interface Specifications
Specification Value
Front Panel Programming
Stepless aluminum rotary knobs and keypad
Computer Interface
RS232, D-sub DB-9, female (Standard)
LXI TCP/IP Ethernet RJ45 (Option +LXI)
IEEE-488 GPIB (Option +GPIB)
External User I/O Port
37-pin D-sub DB-37, female
Referenced to Earth ground; isolated from power supply output
See User Manual for pin layout
Remote Sense Limits (Wired)

Available for models ≤ 1000 Vdc without High Isolation Output (+ISO) option

3% maximum voltage drop from output to load
Accuracy Specifications
Specification Value
Voltage Programming Accuracy
± 0.075% of max rated voltage
Over Voltage Trip Programming Accuracy
± 0.075% of max rated voltage
Current Programming Accuracy
± 0.075% of max rated current
Over Current Trip Programming Accuracy
± 0.075% of max rated current
Voltage Readback Accuracy
± 0.2% of max rated voltage
Current Readback Accuracy
± 0.2% of max rated current
External User I/O Specifications
Specification Value
Analog Programming and Monitoring Levels
0-10 Vdc
Analog Output Impedances
Voltage output monitoring: 100 Ω
Current output monitoring: 100 Ω
+10V reference: 1 Ω
Digital Programming and Monitoring Limits
Input: 0 to 5 Vdc, 10 kΩ input impedance
Output: 0 to 5 Vdc, 5 mA drive capacity
Physical Specifications
Specification Value
Size and Weight

100 kW Models

Floor-standing double-bay 19″ cabinet with casters
67″ H x 48″ W x 31.5″ D (170.2 x 121.9 x 80.0 cm)
1600 lbs (725.8 kg)
Size and Weight

150 kW Models

Floor-standing double-bay 19″ cabinet with casters
67″ H x 48″ W x 31.5″ D (170.2 x 121.9 x 80.0 cm)
2100 lbs (952.5 kg)
Size and Weight

250 kW Models

Floor-standing triple-bay 19″ cabinet with casters
67″ H x 72″ W x 31.5″ D (170.2 x 182.9 x 80.0 cm)
3300 lbs (1496.9 kg)
Environmental Specifications
Specification Value
Ambient Operating Temperature
0°C to 50°C
Storage Temperature
-25°C to +85°C
Humidity
Relative humidity up to 95% non-condensing
Temperature Coefficient
0.04%/°C of maximum output voltage
0.06%/°C of maximum output current
Air Flow
Front and rear inlet, top exhaust
Regulatory Specifications
Specification Value
EMC
Complies with 2014/30/EU (EMC Directive)
CISPR 22 / EN 55022 Class A
Safety
Complies with EN61010-1 and 2014/35/EU (Low Voltage Directive)
CE Mark
Yes
RoHS Compliant
Yes

No Reviews Yet

Write a Review

Share your thoughts. Be the first to leave a review.

Be the first to review “Magna-Power MT Series”

Your email address will not be published. Required fields are marked *