Franklin Grid INCON 1511 LTC

POAExcluding Tax

Request a Quote

Description

Description

The Franklin Grid INCON® 1511-LTC provides basic LTC tap position monitoring using the LTC’s slide wire position feedback device. As the LTC changes taps, the moveable contact picks up the voltage divided through the resistors in the slide wire, so that each tap has its own specific voltage.

THE UTILITY INDUSTRY’S STANDARD

With over 40 years of proven service in over 33,000 utility transformers around the globe, the 1250-LTC does so much more than just monitor tap position. It is a vital tool that utilities use to predict transformer maintenance and prevent the failure of their LTC’s.

HIGHLIGHTS & TECHNOLOGY
  • Receives signal from a resistive drumswitch or “Slidewire” transmitter, 60 ohms min. total resistance
  • Provides a more reliable reading of the transmitter through software filtering and higher 24V signal strength
  • Optional RS-232 port
  • Optional High/Low limit relays function as programmable drag-hand contacts
  • Outputs interface to PLCs, SCADA RTUs and substation computers
MODEL COMPARISON
LTC MONITOR 1250B 1250-LTC 1511-LTC
Applications Transformer LTC Position, Hydro Dam Gate Position, Dam Head/Tail Water Level, Industrial Rotary Power Transformer LTC Position, LTC Position Data Collection Transformer LTC Position
Transducer Type Synchro (1292) Synchro (1292) Resistance Switch (Slidewire)
Input Signal 0-90 VAC, 50/60 Hz 0-90 VAC, 50/60 Hz 0-24 VDC

Specification

Resolution (1250B & 1250-LTC)  

± 0.001% of full scale or 6 arc minutes

Accuracy       

+/-0.02% of full scale, maximum (0.01% typical)

Temperature Drift 

+/-0.01% per °C

Operating Temperature

0 ° to 55 °C

Humidity

10% – 90% non condensing

Weight   

24 ounces

Voltage  

117 +/- 10%

Frequency     

47 – 63 Hz

Load      

8 Watts, maximum

Display Type 

5-digit LED

Digit Height   

0.56 inch (14.2 mm)

Viewing Distance  

23 feet

Decimal Point (1250B)  

Field programmable

Optional Analog Outputs     

+/- 1 mA, 0-1 mA, 0-2 mA, 4-20 mA (requires 15 to 24 VDC external loop power)

Compliance   

10 Volts (0-1 mA, ± 1mA, 0-2 mA)

500 Ohms (4-20 mA)

5 mA (0-10 VDC, ± 10 VDC) 1511-LTC

Resolution    

12 bits (± 0.025% of full scale)

Optional Hi/Lo Relay Contact Rating  

3A @ 125/250 VAC (resistive), 30 VDC

Communication Options     

RS-232 (ASCII)

RS-485 Full Duplex (MODBUS)

No Reviews Yet

Write a Review

Share your thoughts. Be the first to leave a review.

Be the first to review “Franklin Grid INCON 1511 LTC”

Your email address will not be published. Required fields are marked *