Franklin Grid INCON 1250B

POAExcluding Tax

Request a Quote

Description

Description

The Franklin Grid INCON® 1250B is a versatile programmable position monitor. Its main application is for Transformer LTC position monitoring, but its non-linear conversion table gives it the ability to convert non-linear rotary motion into a linear scale for additional applications.

THE UTILITY INDUSTRY’S STANDARD

With over 40 years of proven service in over 33,000 utility transformers around the globe, the 1250-LTC does so much more than just monitor tap position. It is a vital tool that utilities use to predict transformer maintenance and prevent the failure of their LTC’s.

HIGHLIGHTS & TECHNOLOGY
  • Receives a signal from a synchro transmitter (1292 series)
  • Provides absolute position feedback
  • Displays tap position and transmit this information over analog and serial lines
  • Works with any LTC or voltage regulator
  • Includes a software draghand feature to report highest and lowest tap position
  • Programmable through the serial port or front panel
  • Provides an analog output to SCADA or tap controller
MODEL COMPARISON
LTC MONITOR 1250B 1250-LTC 1511-LTC
Applications Transformer LTC Position, Hydro Dam Gate Position, Dam Head/Tail Water Level, Industrial Rotary Power Transformer LTC Position, LTC Position Data Collection Transformer LTC Position
Transducer Type Synchro (1292) Synchro (1292) Resistance Switch (Slidewire)
Input Signal 0-90 VAC, 50/60 Hz 0-90 VAC, 50/60 Hz 0-24 VDC

Specification

Resolution (1250B & 1250-LTC)  

± 0.001% of full scale or 6 arc minutes

Accuracy       

+/-0.02% of full scale, maximum (0.01% typical)

Temperature Drift 

+/-0.01% per °C

Operating Temperature

0 ° to 55 °C

Humidity

10% – 90% non condensing

Weight   

24 ounces

Voltage  

117 +/- 10%

Frequency     

47 – 63 Hz

Load 8 Watts, maximum

Display Type 

5-digit LED

Digit Height   

0.56 inch (14.2 mm)

Viewing Distance  

23 feet

Decimal Point (1250B)  

Field programmable

Optional Analog Outputs     

+/- 1 mA, 0-1 mA, 0-2 mA, 4-20 mA (requires 15 to 24 VDC external loop power)

Compliance   

10 Volts (0-1 mA, ± 1mA, 0-2 mA)

500 Ohms (4-20 mA)

5 mA (0-10 VDC, ± 10 VDC) 1511-LTC

Resolution    

12 bits (± 0.025% of full scale)

Optional Hi/Lo Relay Contact Rating  

3A @ 125/250 VAC (resistive), 30 VDC

Communication Options     

RS-232 (ASCII)

RS-485 Full Duplex (MODBUS)

No Reviews Yet

Write a Review

Share your thoughts. Be the first to leave a review.

Be the first to review “Franklin Grid INCON 1250B”

Your email address will not be published. Required fields are marked *