FLIR A50/A70 Image Streaming-Fixed-Mount Thermal Camera

IMPROVE PRODUCTION AND QUALITY: Quickly access thermal characteristics, with up to 640 × 480 (307,200 pixels) resolution and ±2°C accuracy, allowing users to optimize production settings and product quality.

TROUBLE-FREE INTEGRATION: GigE Vision and GenICam compliant for camera control and thermal/visual image video streaming over Ethernet into third-party machine vision applications.

RUGGED AND EASY TO INSTALL: Install the lightweight, IP66 rated camera with M8/12 connectors in any location – with multiple mounting options.

POAExcluding Tax

Request a Quote

Description

Description

FLIR A50 and A70 Thermal Image Streaming Cameras are the right choice for users who want camera control capabilities and image streaming over Ethernet, as well as flexibility to perform analytics and raw data collection on thermal characteristics using preferred software applications.

With options for Wi-Fi, an integrated visual camera, compressed radiometric image streaming, and ONVIF S compatibility (advanced version only), these small and lightweight fixed-focus automation cameras will optimize process control and quality assurance to improve yield, product quality, through-put time, and lower costs.

To order this item please contact us directly:
Email: sales@butlertech.ie
Phone: +353 1 6292620

Specification

Digital I/O connector type

M12 12-pin A-coded, Male (shared with external power)

Digital Inputs

2x opto-isolated, Vin(low)= 0–1.5 V, Vin(high)= 3–25 V

Digital Output Purpose

Programmatically set; fault (NC)

Digital Outputs

3x opto-isolated, 0–48 V DC, max. 350 mA; solid-state opto relay; 1x dedicated as Fault output (NC)

Encoding

RTSP video streaming: H.264 / MPEG4 / MJPEG RTSP radiometric streaming: compressed JPEG-LS, FLIR radiometric GVSP video streaming: uncompressed GVSP radiometric streaming: temperature linear and FLIR radiometric

Ethernet Interface

Wired, Wi-Fi (optional)

WiFi

Optional feature purchased separately. RP-SMA, female connector

EMC

  • ETSI EN 301 489-1 (radio) • ETSI EN 301 489-17 (radio) • EN 61000-4-8 (magnetic field) • FCC 47 CFR Part 15 Class B (emission US) • ISO 13766-1 (EMC – Earth-moving and building construction machinery) • EN ISO 14982 (EMC – Agricultural and forestry machinery)

f-number

1.4

Image Fequency

30 Hz

Thermal Sensitivity/NETD

<35 mK

Accuracy

±2°C (±3.6°F) or ±2% of reading, for ambient temperature 15°C–35°C (59°F–95°F) and object temperature above 0°C (32°F)

Alarm Functions

NA

Alarm Output

NA

COMMUNICATION & DATA STORAGE

Digital I/O connector type

M12 12-pin A-coded, Male (shared with external power)

Digital I/O isolation voltage

500 VRMS

Digital input purpose

NUC; NUC disable; image TAG (Start, Stop, General); image flow control (acc. SFNC 2.3): • Single frame (on trigg) • Multiframe (on trigg) • Continuous

Digital Inputs

2x opto-isolated, Vin(low)= 0–1.5 V, Vin(high)= 3–25 V

Digital Output Purpose

Programmatically set; fault (NC)

Digital Outputs

3x opto-isolated, 0–48 V DC, max. 350 mA; solid-state opto relay; 1x dedicated as Fault output (NC)

Encoding

RTSP video streaming: H.264 / MPEG4 / MJPEG RTSP radiometric streaming: compressed JPEG-LS, FLIR radiometric GVSP video streaming: uncompressed GVSP radiometric streaming: temperature linear and FLIR radiometric

Ethernet

For control, result, image, and power

Ethernet Communication

  • GigE Vision ver. 1.2 • Client API GenICam compliant • TCP/IP socket-based FLIR proprietary

Ethernet Connector Type

M12 8-pin X-coded, female; RP-SMA, female

Ethernet Interface

Wired, Wi-Fi (optional)

Ethernet Power

Power over Ethernet, PoE IEEE 802.3af class 3

Ethernet Protocols

  • IEEE 1588 • SNMP • TCP, UDP, SNTP, RTSP, RTP, HTTP, HTTPS, ICMP, IGMP, sftp (server), FTP (client), SMTP, DHCP, MDNS (Bonjour), uPnP, GVSP, GVCP

Ethernet Standard

IEEE 802.3

Ethernet Type

1000 Mbps

Image Storage

NA

Multicast

Yes

ONVIF Profile S Compliant

Yes

RS-232

M8 A-coded, male connector

Serial Communication

Pan & Tilt control. Pelco D standard HW interface: RS232 and RS485 exclusively

WiFi

Optional feature purchased separately. RP-SMA, female connector

IMAGING & OPTICAL

Contrast Enhancement

FSX® / Histogram equalization (IR only)

Detector Pitch

17 µm

Field of view (FOV)

29° × 22°

f-number

1.4

Focal Length

14.3 mm (0.56 in)

Focal Plane Array (FPA)

Uncooled microbolometer

Focus

Fixed, adjustable with included tool

Image Fequency

30 Hz

IR Resolution

464 × 348

Minimum Focus Distance

0.25 m (0.82 ft)

MSX

Yes, included in visual camera option

Overlay

Without

Radiometric IR video streaming

GigE Vision and RTSP

Readout

No measurements readouts, only streamed video

Spectral Range

7.5–14 µm

Streaming Resolution

RTSP video streaming, source 0: 640 × 480 pixels RTSP video streaming, source 1: 1280 × 960 pixels RTSP radiometric streaming: 464 × 348 pixels GVSP video streaming: 640 × 480 pixels GVSP radiometric streaming: 464 × 348 pixels

Thermal Sensitivity/NETD

<35 mK

Video Streaming

RTSP or GVSP (GigE Vision) protocols

Visible Camera

Optional accessory

MEASUREMENT & ANALYSIS

Accuracy

±2°C (±3.6°F) or ±2% of reading, for ambient temperature 15°C–35°C (59°F–95°F) and object temperature above 0°C (32°F)

Alarm Functions

NA

Alarm Output

NA

Atmospheric transmission correction

Based on inputs of distance, atmospheric temperature, and relative humidity

Automatic hot & cold detection

NA

Measurement Corrections

NA

Measurement Presets

NA

Measurement Tools

NA

Object Temperature Range

–20 to 175°C (–4 to 347°F) 175 to 1000°C (347 to 1832°F)

GENERAL

Base Mounting

4 x M2.5 direct into camera or 4x 10-32 UNF onto bottom cooling plate

Housing material

Aluminium

Size (L x W x H)

107 × 67 × 57 mm (4.21 × 2.64 × 2.24 in)

Weight

519g (1.14lb) without bottom cooling plate

ENVIRONMENTAL & CERTIFICATIONS

Corrosion

  • ISO 12944 C4 G or H • EN60068-2-11

EMC

  • ETSI EN 301 489-1 (radio) • ETSI EN 301 489-17 (radio) • EN 61000-4-8 (magnetic field) • FCC 47 CFR Part 15 Class B (emission US) • ISO 13766-1 (EMC – Earth-moving and building construction machinery) • EN ISO 14982 (EMC – Agricultural and forestry machinery)

Encapsulation

IEC 60529 and IP66

Humidity (Operating and Storage)

IEC 60068-2-30/24 hours, 95% relative humidity, 25–40°C (77–104°F)/2 cycles EN60068-2-38

Operating Temperature Range

–20 to 50°C (–4 to 122°F) Bottom cooling plate is needed in temperatures above 40°C (104°F). Maximum internal temperature sensor: 70°C (158°F)

Radio Spectrum

  • FCC 47 CFR Part 15 Class C (2.4 GHz band US) • FCC 47 CFR Part 15 Class E (5 GHz band US) • RSS-247 (2.4 GHz and 5 GHz band Canada) • ETSI EN 300 328 V2.1.1 (2.4 GHz band EU) • ETSI EN 301 893 V2.1.1 (5 GHz band EU)

Shock

IEC 60068-2-27, 25 g

Tripod Mounting

4 x M2.5 direct into camera or 4x 10-32 UNF onto bottom cooling plate

Vibration

  • IEC 60068-2-6, 0.15 mm at 10–58 Hz and 2 g at 58–500 Hz, sinusoidal • IEC 61373 Cat 1 (Railway)

POWER

External Power Operation

24/48 V DC 8 W max

External Voltage

Allowed range 18–56 V DC

Power Connection

M12 12-pin A-coded, male (shared with Digital I/O)

Power Consumption

  • 7.5 W at 24 V DC typical • 7.8 W at 48 V DC typical • 8.1 W at 48 V PoE typical

No Reviews Yet

Write a Review

Share your thoughts. Be the first to leave a review.

Be the first to review “FLIR A50/A70 Image Streaming-Fixed-Mount Thermal Camera”

Your email address will not be published. Required fields are marked *