The following specifications are subject to change without notice. Unless otherwise noted, all specifications measured at the product’s maximum ratings.
AC Input Specifications
Specification |
Value |
1Φ, 2-wire + ground |
100-240 Vac (UI: Universal input; 1.5 kW Models)
208-240 Vac (UI2: Universal input 2; 2.6 kW Models) |
3Φ, 3-wire + ground |
208 Vac (operating range 187 to 229 Vac)
240 Vac (operating range 216 to 264 Vac)
380 Vac (operating range 342 to 440 Vac)
415 Vac (operating range 373 to 456 Vac)
440 Vac (operating range 396 to 484 Vac)
480 Vac (operating range 432 to 528 Vac) |
|
50 Hz to 400 Hz |
|
0.99 at maximum power for models with 1Φ AC input; Active-PFC
> 0.82 at maximum power for models with 3Φ AC input |
|
±2500 Vdc, maximum input voltage to ground |
DC Output Specifications
Specification |
Value |
|
Model specific. Refer to chart of available models. |
|
Voltage mode: ± 0.004% of full scale
Current mode: ± 0.02% of full scale |
|
Voltage mode: ± 0.01% of full scale
Current mode: ± 0.04% of full scale |
|
± 0.10% for 8 hrs. after 30 min. warm-up |
|
84% to 95%
Model specific. Refer to chart of available models. |
Standard Models |
< 170 ms for a programmed output voltage change from 0 to 63%
< 200 ms for a programmed output current change from 0 to 63% |
Models with High Slew Rate Output (+HS) Option |
< 5 ms for a programmed output voltage change from 0 to 63%
< 10 ms for a programmed output current change from 0 to 63% |
Standard Models |
3 Hz with remote analog voltage programming
2 Hz with remote analog current programming |
Models with High Slew Rate Output (+HS) Option |
60 Hz with remote analog voltage programming
45 Hz with remote analog current programming |
|
±1500 Vdc, maximum output voltage to ground |
Programming Interface Specifications
Specification |
Value |
|
Stepless aluminum rotary knobs and keypad |
|
RS232, D-sub DB-9, female (Standard)
LXI TCP/IP Ethernet RJ45 (Option +LXI)
IEEE-488 GPIB (Option +GPIB) |
Analog and Digital Programming |
37-pin D-sub DB-37, female
Referenced to Earth ground; isolated from power supply output
See User Manual for pin layout |
Remote Sense Limits (Wired)
Available for models ≤ 1000 Vdc |
3% maximum voltage drop from output to load |
Accuracy Specifications
Specification |
Value |
Voltage Programming Accuracy
|
± 0.075% of max rated voltage |
Over Voltage Trip Programming Accuracy
|
± 0.075% of max rated voltage |
Current Programming Accuracy
|
± 0.075% of max rated current |
Over Current Trip Programming Accuracy
|
± 0.075% of max rated current |
Voltage Readback Accuracy
|
± 0.2% of max rated voltage |
Current Readback Accuracy
|
± 0.2% of max rated current |
External User I/O Specifications
Specification |
Value |
Analog Programming and Monitoring Levels
|
0-10 Vdc |
|
Voltage output monitoring: 100 Ω
Current output monitoring: 100 Ω
+10V reference: 1 Ω |
Digital Programming and Monitoring Limits
|
Input: 0 to 5 Vdc, 10 kΩ input impedance
Output: 0 to 5 Vdc, 5 mA drive capacity |
Physical Specifications
Specification |
Value |
|
EIA-310 |
|
Included |
1.5 kW Models |
1U
1.75″ H x 19″ W x 24″ D (4.4 x 48.3 x 61.0 cm)
32 lbs (14.52 kg) |
2.6 kW Models |
1U
1.75″ H x 19″ W x 24″ D (4.4 x 48.3 x 61.0 cm)
34 lbs (15.42 kg) |
4 kW Models |
1U
1.75″ H x 19″ W x 24″ D (4.4 x 48.3 x 61.0 cm)
35 lbs (15.88 kg) |
6 kW Models |
1U
1.75″ H x 19″ W x 24″ D (4.4 x 48.3 x 61.0 cm)
35 lbs (15.88 kg) |
8 kW Models |
1U
1.75″ H x 19″ W x 24″ D (4.4 x 48.3 x 61.0 cm)
36 lbs (16.33 kg) |
10 kW Models |
1U
1.75″ H x 19″ W x 24″ D (4.4 x 48.3 x 61.0 cm)
37 lbs (16.78 kg) |
Environmental Specifications
Specification |
Value |
Ambient Operating Temperature
|
-25°C to 50°C |
|
-40°C to +85°C |
|
Relative humidity up to 95% non-condensing |
|
0.04%/°C of maximum output voltage
0.06%/°C of maximum output current |
|
Side air inlet, rear exhaust |
Regulatory Specifications
Specification |
Value |
|
Complies with 2014/30/EU (EMC Directive)
CISPR 22 / EN 55022 Class A |
|
NRTL Listed, TÜV SÜD Certificate U8 123461 0001
Tested to UL 61010-1:2012/R:2019-07 and CSA C22.2 No. 61010:2012/A1:2018-11
Complies with EN61010-1 and 2014/35/EU (Low Voltage Directive) |
|
Yes |
|
Yes |
No Reviews Yet